Platforms to show: All Mac Windows Linux Cross-Platform

Back to OldPhidgetPHSensorMBS class.

OldPhidgetPHSensorMBS.Constructor

Type Topic Plugin Version macOS Windows Linux iOS Targets
method Phidgets MBS Phidgets Plugin 7.7 ✅ Yes ✅ Yes ✅ Yes ❌ No Desktop, Console & Web
The constructor.

On success the handle value is not zero.
The Lasterror property is set.

OldPhidgetPHSensorMBS.getPH as Double

Type Topic Plugin Version macOS Windows Linux iOS Targets
method Phidgets MBS Phidgets Plugin 7.7 ✅ Yes ✅ Yes ✅ Yes ❌ No Desktop, Console & Web
Returns the current pH.

The Lasterror property is set.
Valid range is -10 to 10.
Note that this value defaults to -20. Applications not wishing to encounter this value should use Change Handlers instead of polling the device for data.

OldPhidgetPHSensorMBS.getPHChangeTrigger as Double

Type Topic Plugin Version macOS Windows Linux iOS Targets
method Phidgets MBS Phidgets Plugin 7.7 ✅ Yes ✅ Yes ✅ Yes ❌ No Desktop, Console & Web
Gets the amount of change that should exist between the last reported value and the current value before an PHChange event is fired.

The Lasterror property is set.

OldPhidgetPHSensorMBS.getPHMax as Double

Type Topic Plugin Version macOS Windows Linux iOS Targets
method Phidgets MBS Phidgets Plugin 8.4 ✅ Yes ✅ Yes ✅ Yes ❌ No Desktop, Console & Web
Gets the maximum PH that the sensor could report.

The Lasterror property is set.

OldPhidgetPHSensorMBS.getPHMin as Double

Type Topic Plugin Version macOS Windows Linux iOS Targets
method Phidgets MBS Phidgets Plugin 8.4 ✅ Yes ✅ Yes ✅ Yes ❌ No Desktop, Console & Web
Gets the minimum PH that the sensor could report.

The Lasterror property is set.

OldPhidgetPHSensorMBS.getPotential as Double

Type Topic Plugin Version macOS Windows Linux iOS Targets
method Phidgets MBS Phidgets Plugin 7.7 ✅ Yes ✅ Yes ✅ Yes ❌ No Desktop, Console & Web
Returns the current potential in volts.

The Lasterror property is set.
Range is 0-5v.
2.5v corresponds to a pH of 7.0.

OldPhidgetPHSensorMBS.getPotentialMax as Double

Type Topic Plugin Version macOS Windows Linux iOS Targets
method Phidgets MBS Phidgets Plugin 8.4 ✅ Yes ✅ Yes ✅ Yes ❌ No Desktop, Console & Web
Gets the maximum potential that can be sensed.

The Lasterror property is set.

OldPhidgetPHSensorMBS.getPotentialMin as Double

Type Topic Plugin Version macOS Windows Linux iOS Targets
method Phidgets MBS Phidgets Plugin 8.4 ✅ Yes ✅ Yes ✅ Yes ❌ No Desktop, Console & Web
Gets the minimum potential that can be sensed.

The Lasterror property is set.

OldPhidgetPHSensorMBS.setPHChangeTrigger(value as Double)

Type Topic Plugin Version macOS Windows Linux iOS Targets
method Phidgets MBS Phidgets Plugin 7.7 ✅ Yes ✅ Yes ✅ Yes ❌ No Desktop, Console & Web
Specifies the amount of change that should exist between the last reported value and the current value before an OnPHChange event is fired.

The Lasterror property is set.

OldPhidgetPHSensorMBS.setTemperature(value as Double)

Type Topic Plugin Version macOS Windows Linux iOS Targets
method Phidgets MBS Phidgets Plugin 7.7 ✅ Yes ✅ Yes ✅ Yes ❌ No Desktop, Console & Web
Sets the ambient temperature of the PH sensor for increased accuracy.

This value defaults to 20 degrees celcius which is applicable for most applications.
The Lasterror property is set.